Avaya S8700 Maintenance Manual page 668

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands
long
repeat number
clear
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
'login id':'command' has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
7-412
Issue 1 May 2002
This will execute a more comprehensive and longer version of the
diagnostic tests. This may involve both destructive and nondestructive
tests.
The "number" specifies how many times each test in the sequence is to be
repeated. "Number" may be any integer between 1 and 100.
This option causes the test sequence (short or long) to repeat until the
alarm is cleared or a single test in the sequence fails. The long clear option
forces a clear of all alarms if no errors are encountered during testing. The
short clear option only clears alarms pertinent to tests in the short
sequence.
!
WARNING:
Executing a clear with short option, may not clear all alarms
even if all tests pass.
!
WARNING:
Since the "clear long" options clear all counters if tests pass, it
is possible for firmware counters to be cleared even when a
problem exists. In some cases customer service might
degrade since calls may be routed over defective equipment.