Section 12 16-Bit Free-Running Timer (FRT)
φ
FRC
Overflow signal
OVF
Figure 12.13 Timing of Overflow Flag (OVF) Setting
12.5.9
Automatic Addition Timing
When the OCRAMS bit in TOCR is set to 1, the contents of OCRAR and OCRAF are
automatically added to OCRA alternately, and when an OCRA compare-match occurs a write to
OCRA is performed. Figure 12.14 shows the OCRA write timing.
φ
FRC
OCRA
OCRAR, OCRAF
Compare-match
signal
Rev. 3.00 Jan 25, 2006 page 306 of 872
REJ09B0286-0300
H'FFFF
N
N
Figure 12.14 OCRA Automatic Addition Timing
H'0000
A
N +1
N + A