Renesas H8S/2158 User Manual page 554

16-bit single-chip microcomputer h8s family/h8s/2100 series
Table of Contents

Advertisement

2
Section 17 I
C Bus Interface (IIC)
Bit
Bit Name
Initial Value
5
STOP
0
4
ABRT
0
3
ALST
0
Rev. 3.00 Jan 25, 2006 page 500 of 872
REJ09B0286-0300
R/W
Description
R/(W) * Stop Condition Detection
0: No stop condition is detected
1: Stop condition is detected
[Clearing conditions]
When ICCMD is written to
When 0 is written to STOP after reading STOP = 1
[Setting condition]
When a stop condition is detected
R
Abort
0: Normal end
1: Abort
[Clearing conditions]
When ICCMD is written to
When 0 is written to ABRT after reading ABRT = 1
[Setting condition]
When a start/stop condition is detected during data
transfer
R/(W) * Arbitration Lost
0: Normal operation
1: Arbitration loss is generated
[Clearing conditions]
When ICCMD is written to
When 0 is written to ALST after reading ALST = 1
[Setting condition]
When arbitration loss is generated in master mode
(1) Internal SDA disagrees with the SDA pin level
at rise of SCL
(2) Internal SDA is high when the start condition is
detected

Advertisement

Table of Contents
loading

Table of Contents