An-Ln-Pt (Analog Line Port); Ringing Caused By Maintenance Testing - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 49. TEST #36 Station Status and Translation Audits and Updates Continued
Error
Code
2100
1
7

AN-LN-PT (Analog Line Port)

Table 50. AN_LN_PT (Analog Line Port)
MO Name (in
Alarm Log)
AN-LN-PT
AN-LN-PT
Note: You must consult local records for the location and designation of the
equipment rack where the G700 is mounted.
The MM711 Analog Trunk and Line Media Module provides 8 ports, each of which may be
administered in any of several ways, as described in maintenance object MG-ANA .

Ringing Caused by Maintenance Testing

Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this ringing
disturbs the customer or the terminal equipment, disable it in the Tests field of the change
station extension form. Be aware that this action also disables Tests #6, 7, and 35 on some
software releases.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/Recommendation
Result
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
This failure does not indicate a hardware problem. The switchhook
audit failed, this condition may occur when the audit is performed at
the same time that the terminal equipment goes off-hook.
Enter test external-device-alarm port GGGVSpp to determine if the
port is reporting an EXT-DEV failure before retesting. Wait until the
port has no EXT-DEV failure before retesting
If the port has no EXT-DEV failure, retry the command at 1-minute
intervals for a maximum of 5 times.
FAIL
The translation update failed. This does not indicate a hardware
problem but may be an internal software error.
PASS
The software and the port processor have the same status.
Alarm Level
MIN
WRN
Initial Command to
Run*
test port GGGVSPP
test port GGGVSPP
AN-LN-PT (Analog Line Port)
Full Name of
MO
Analog Line Port
Analog Line Port
105