Data Transfer Operations:
• SCI initialization (clocked synchronous mode)
Before transmitting and receiving data, you should first clear the TE and RE bits in SCR to 0, then initialize the SCI as
described below.
When the operating mode, transfer format, etc., is changed, the TE and RE bits must be cleared to 0 before making the
change using the following procedure. When the TE bit is cleared to 0, the TDRE flag is set to 1 and TSR is initialized.
Note that clearing the RE bit to 0 does not change the contents of the RDRF, PER, FER, and ORER flags, or the
contents of RDR.
Figure 14-15 shows a sample SCI initialization flowchart.
Clear TE and RE bits in SCR to 0
Set CKE1 and CKE0 bits in SCR
Set data transfer format in
Set TE and RE bits in SCR to 1, and
set RIE, TIE, TEIE, and MPIE bits
Note: In simultaneous transmit and receive operations, the TE and RE bits should
Rev.6.00 Oct.28.2004 page 506 of 1016
REJ09B0138-0600H
Start initialization
(TE, RE bits 0)
SMR and SCMR
Set value in BRR
Wait
1-bit interval elapsed?
Yes
<Transfer start>
both be cleared to 0 or set to 1 simultaneously.
Figure 14-15 Sample SCI Initialization Flowchart
[1] Set the clock selection in SCR. Be sure
to clear bits RIE, TIE, TEIE, and MPIE,
TE and RE, to 0.
[2] Set the data transfer format in SMR
and SCMR.
[1]
[3] Write a value corresponding to the bit
rate to BRR. Not necessary if an
external clock is used.
[2]
[4] Wait at least one bit interval, then set
the TE bit or RE bit in SCR to 1.
Also set the RIE, TIE, TEIE, and MPIE
[3]
bits.
Setting the TE and RE bits enables the
TxD and RxD pins to be used.
No
[4]