Renesas H8S Series Hardware Manual page 964

16-bit single-chip microcomputer
Hide thumbs Also See for H8S Series:
Table of Contents

Advertisement

ADCSR—A/D Control/Status Register
Bit
Initial value
Read/Write
A/D End Flag
0
[Clearing conditions]
• When 0 is written to the ADF flag after reading ADF = 1
• When the DTC is activated by an ADI interrupt, and ADDR is read
1
[Setting conditions]
• Single mode: When A/D conversion ends
• Scan mode: When one round of conversion has been performed on all specified channels
Note: * Can only be written with 0 for flag clearing.
Rev.6.00 Oct.28.2004 page 936 of 1016
REJ09B0138-0600H
:
7
6
ADF
ADIE
:
0
0
:
R/(W)*
R/W
A/D Start
A/D Interrupt Enable
0
A/D conversion end interrupt (ADI) request disabled
1
A/D conversion end interrupt (ADI) request enabled
H'FF98
5
4
3
ADST
SCAN
CKS
0
0
0
R/W
R/W
R/W
Channel Select
Group
select
CH2
CH1
0
1
Group Select
0
Conversion time= 266 states (max.)
1
Conversion time= 134 states (max.)
Scan Mode
0
Single mode
1
Scan mode
0
A/D conversion stopped
1
• Single mode: A/D conversion is started. Cleared to 0
automatically when conversion ends
• Scan mode: A/D conversion is started. Conversion continues
sequentially on the selected channels until ADST is cleared to
0 by software, a reset, or transition to standby mode or
module stop mode
A/D Converter
2
1
CH2
CH1
0
0
R/W
R/W
Channel
select
Single Mode
Group Mode
CH0
0
0
AN0
AN0
1
AN1
AN0, AN1
1
0
AN2
AN0 to AN2
1
AN3
AN0 to AN3
0
0
AN4
AN4
1
AN5
AN4, AN5
1
0
AN6
AN4 to AN6
1
AN7
AN4 to AN7
0
CH0
0
R/W