(2) Control Signal Timing
Table 22-37 lists the control signal timing.
Table 22-37 Control Signal Timing
= 5.0 V ± 10%, AV
Condition B: V
CC
V
= AV
SS
T
= –40 to +85°C (wide-range specifications)
a
Condition C: V
= 3.0 to 5.5 V, AV
CC
V
= AV
SS
T
= –40 to +85°C (wide-range specifications)
a
Item
RES setup time
RES pulse width
NMI setup time
NMI hold time
NMI pulse width (exiting
software standby mode)
IRQ setup time
IRQ hold time
IRQ pulse width (exiting
software standby mode)
Rev.6.00 Oct.28.2004 page 760 of 1016
REJ09B0138-0600H
= 5.0 V ± 10%, V
CC
= 0 V, ø = 2 to 20 MHz, T
SS
= 3.0 to 5.5 V, V
CC
= 0 V, ø = 2 to 13 MHz, T
SS
Symbol
t
RESS
t
RESW
t
NMIS
t
NMIH
t
NMIW
t
IRQS
t
IRQH
t
IRQW
= 4.5 V to AV
ref
CC
= –20 to +75°C (regular specifications),
a
= 3.0 V to AV
,
ref
CC
= –20 to +75°C (regular specifications),
a
Condition B
Condition C
Min
Max
Min
Max
200
—
200
—
20
—
20
—
150
—
250
—
10
—
10
—
200
—
200
—
150
—
250
—
10
—
10
—
200
—
200
—
,
Unit
Test Conditions
ns
Figure 22-70
t
cyc
ns
Figure 22-71
ns
ns
ns
ns