Maintenance-Object Repair Procedures
t. Error Type 3999—The circuit pack sent a large number of control-channel
messages to the switch within a short period of time.
Error Type 1538
(hyperactivity)
also present?
Y
N
Shutting Down NT on the TN802
Before removing the TN802 circuit pack from the carrier, shut Windows NT
down first by following either procedure described in
Table 8-420. Windows NT shutdown procedures
Step
Faceplate button
1.
Push the recessed button on the front
faceplate and hold it in.
2.
"M shut" flashes on the LCD display
3.
When shutdown is complete, "MSHUT #"
displays ("#" is blinking).
4.
Remove the circuit pack.
5.
6.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order they are presented in
clearing error codes associated with the NPE Connection Audit test (#50), you
may also clear errors generated from other tests in the testing sequence.
8-1060
Issue 1 May 2002
Then the switch:
Takes the circuit pack out-of-service due to hyperactivity
Does not take the circuit pack out-of-service, but the circuit
pack has generated 50% of the messages necessary to be
considered hyperactive. This may be normal during heavy
traffic periods.
PC interface
Click on the "Start" button in the lower
left-hand corner.
Click on "Shut Down."
Choose the "Shut down the computer?" radio
button.
Click on "OK."
Wait for the message indicating that shutdown
is complete.