Mapd-Bd (Mapd Interface Circuit Pack Tn802) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

MAPD-BD (MAPD Interface Circuit Pack TN802)

MAPD-BD (MAPD Interface Circuit
Pack TN802)
MO's Name
Alarm
(in Alarm Log)
Level
MAPD-BD
MAJOR
MAPD-BD
MINOR
MAPD-BD
WARNING
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
The TN802 Multiple Application Platform (MAP-D) circuit pack allows sending
voice and fax from S8700 Multi-Connect through the Internet to another S8700
Multi-Connect also having this feature or to other PBXs that are equipped with the
Internet Telephony server (ITS-E).
Throughout this section the term TN802 means the MAP-D IP trunk circuit pack.
Be sure to observe these special considerations for the TN802:
Port alarms on this circuit pack display as "TIE-DS1" in the Alarm and Error
logs.
The reset board command reboots the MAPD PC CPU, but busyout
board only busies out every emulated port on the board.
Switch resets that take the switch out of service for more than 20 seconds
also cause the MAPD's PC to reboot, which takes several minutes to
complete.
Switch-Demanded Tests
Switch-demanded diagnostic tests on the TN802 do not run unless the Internet
trunking application is running on Windows NT
555-233-143
Initial SAT Command to
1
Run
test board UUCSS sh
test board UUCSS l
test board UUCSS sh
Full Name of MO
MAPD Interface circuit pack
MAPD Interface circuit pack
MAPD Interface circuit pack
TM
, located on the circuit pack.
Issue 1 May 2002
8-1039

Advertisement

Table of Contents
loading