MAINT (PN's Maintenance Circuit Pack)
Battery Holdover Hardware
Verification Test (#311)
The hardware/firmware vintage of the PN's TN775D Maintenance boards does
not support battery holdover for all carriers. This test checks to see if PN cabinet
battery holdover for all carriers has been administered in error. If battery
holdover is administered for all carriers, the test will fail and a WARNING alarm
will be raised against this MO.
Table 8-411. TEST #303 PN Maintenance Circuit Pack Sanity Maze Test
Error
Test
Code
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test was not received within the allowable time period.
2029
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The hardware vintage of the PN's Maintenance circuit pack does not support
battery holdover for all carriers.
1. Verify cabinet administration, make sure that the battery holdover feature is
2. Retry the command at 1-minute intervals up to 5 times.
PASS
The cabinet administration shows battery holdover for A carrier only. Also, the
hardware vintage of the PN's TN775D Maintenance board is correct.
555-233-143
NOTE:
This failure indicates that the cabinet administration is set for battery
holdover for all carriers.
administered correctly (That cabinet administration is not set for battery
holdover for all carriers.).