2650
C
175: E1
HAPTER
AND
View
Parameter
Description
Related command:
Example
clear-forward-ack enable
Syntax
View
Parameter
Description
T1 C
C
ONFIGURATION
OMMANDS
E1/T1 interface view
ts-set-number: Number of a created timeslot (TS) group, in the range of 0 to 30.
The number of a T1 timeslot group ranges from 0 to 23.
Use the
command to enter R2 CAS view, digital E&M signaling view, or digital
cas
LGS signaling view.
After entering a signaling view, you may configure signaling parameters as
desired. When doing that, assign the same value to the ts-set-number keyword in
commands cas and timeslot-set.
timeslot-set, ani-offset, reverse, select-mode, timer, trunk-direction, and
renew.
# Enter the R2 CAS view of TS group 5.
<Sysname> system-view
[Sysname] controller e1 1/0
[Sysname-e1 1/0] timeslot-set 5 timeslot-list 1-31 signal r2
[Sysname-e1 1/0] cas 5
clear-forward-ack enable
undo clear-forward-ack enable
R2 CAS view
None
Use the
clear-forward-ack enable
respond with a clear-back signal when the originating point (the calling party)
disconnects a call.
Use the
undo clear-forward-ack enable
point to respond with a clear-back signal when the originating point (the calling
party) disconnects a call.
By default, the terminating point does not send clear-back signals to acknowledge
clear-forward signals.
This command applies to R2 signaling only.
In some countries, if the terminating point controls trunk circuit reset in the R2
signaling exchange process, when the calling party disconnects a call and the
originating point sends a clear-forward signal to the terminating point, the
terminating point sends a clear-back signal as an acknowledgement, and then
sends a release guard signal to indicate that the line of the terminating point is
thoroughly released.
command to enable the terminating point to
command to disable the terminating