Parameter
Description
Example

lock

Syntax
View
Parameter
Description
Example
minutes: Specifies timeout time in minutes, in the range 0 to 35791, defaulting to
10 minutes.
seconds: Specifies timeout time in seconds, in the range 0 to 59, defaulting to 0
seconds.
Use the
idle-timeout
the user connection is terminated.
Use the
undo idle-timeout
The default idle-timeout is 10 minutes.
n
The system automatically terminates user's connection if there is no information
interaction between the device and the user in timeout time.
Setting idle-timeout to zero disables the timer and the connection is maintained
whether it is idle or not.
# Set the idle-timeout timer to 1 minute and 30 seconds.
<Sysname> system-view
[Sysname] user-interface console 0
[Sysname-ui-console0] idle-timeout 1 30
lock
User view
None
Use the
command to set a password to prevent unauthorized users from
lock
operating under the active user interface.
After entering the lock command, you are prompted to input a password (up to
16 characters) and then confirm it by inputting the password again. The password
is successfully set only when you input the exact password during the
confirmation. After setting the password, you will be required to input the
password next time you enter the system.
By default, this function is disabled.
# Lock the active user interface.
<Sysname> lock
Please input password<1 to 16> to lock current user terminal interface:
Password:
Again:
command to set the idle-timeout timer. When it expires,
command to restore the default.