H3C MSR 20-20 Command Reference Manual page 2590

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

2590
C
173: V
IP C
HAPTER
O
C
ONFIGURATION
OMMANDS
Table 682 Meaning of the index numbers
Index
Meaning
1
The upper limit of the maximum
value of ROWMAX or COLMAX,
whichever is larger. This limit is used
for detecting the inter-digit delay. A
detected digit is regarded ended only
when max (ROWMAX, COLMAX) <
1.
2
The lower limit of
COLMAX/ROWMAX, where
ROWMAX < COLMAX. An input
signal is recognized as a DTMF digit
only when 10 x
(COLMAX/ROWMAX) > 2.
3
The lower limit of
ROWMAX/COLMAX when COLMAX
Š ROWMAX. The function is similar
to that of index 2. An input signal is
recognized as a DTMF digit only
when 10 x (ROWMAX/COLMAX) >
2.
4
The upper limit of the ratio of the
second largest energy level from the
row frequency group to ROWMAX.
The ratio must be lower than this
limit for the input signal to be
recognized as a DTMF digit.
5
The upper limit of the ratio of the
second largest energy level from the
column frequency group to
COLMAX. The ratio must be lower
than this limit for the input signal to
be recognized as a DTMF digit.
6
The upper limit of
ROW2nd/ROWMAX. An input signal
is recognized as a DTMF digit only
when ROW2nd/ROWMAX < 6.
7
The upper limit of
COL2nd/COLMAX. The ratio must
be lower than this limit for the input
signal to be recognized as a DTMF
digit.
8
The upper limit of the ratio of the
maximum energy level of two extra
specified frequency points to max
(ROWMAX, COLMAX). The ratio
must be greater than this upper limit
for the input signal to be recognized
as a DTMF digit.
9
The lower limit of the DTMF signal
duration. The duration of DTMF key
tone must be larger than this
threshold for the input signal to be
recognized as a DTMF digit.
Value range
Remarks
1 to 4,999, with
The smaller the value is,
a default of 458
the higher the detection
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The larger the value is,
with a default of
the higher the detection
-9 dB.
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The smaller the value is,
with a default of
the higher the detection
-9 dB.
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The smaller the value is,
with a default of
the higher the detection
-9 dB.
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The smaller the value is,
with a default of
the higher the detection
-9 dB.
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The smaller the value is,
with a default of
the higher the detection
-3 dB.
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The smaller the value is,
with a default of
the higher the detection
-12 dB.
reliability is. However,
the sensitivity drops.
-18 to -3 dB,
The smaller the value is,
with a default of
the higher the detection
-12 dB.
reliability is. However,
the sensitivity drops.
30 to 150
The larger the value is,
milliseconds,
the higher the detection
with a default of
reliability is. However,
30 milliseconds.
the sensitivity drops.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msr 20-21Msr 30-16Msr 30-20Msr 30-40Msr 30-60Msr 50 ... Show all

Table of Contents