Callednumber Receive-Method - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

Example

callednumber receive-method

Syntax
View
Parameter
Description
Related command:
Example
# Enable the authorization function for one-stage dialing users.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] aaa-client
[Sysname-voice-aaa] authentication-did
[Sysname-voice-aaa] authorization-did
# Disable the authorization function for one-stage dialing users.
[Sysname-voice-aaa] undo authorization-did
callednumber receive-method { immediate | terminator }
undo callednumber receive-method
Access number view
immediate: Specifies the voice gateway to originate a call immediately it collects
all digits of a called number.
terminator: Specifies users to press the dial terminator # after dialing a called
number.
Use the
callednumber receive-method
collecting digits of a called number.
Use the
undo callednumber receive-method
default.
By default, users need to press the dial terminator # after dialing all digits of a
called number.
This command is applicable to both the one-stage dialing process and two-stage
dialing process. In the terminator mode, the voice gateway can immediately
originate a call only after users dial a called number and press the dial terminator
#, and otherwise, the voice gateway will not originate a call until timeout. In the
immediate mode, the voice gateway can originate a call immediately it collects all
digits of a called number, without waiting users to press the dial terminator #. The
immediate mode simplifies users' operations.
gw-access-number.
# Set the method of collecting digits of called numbers to immediate for the
access number 17909.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] dial-program
[Sysname-voice-dial] gw-access-number 17909
[Sysname-voice-dial-anum17909] callednumber receive-method immediate
command to configure the method of
command to restore the