undo dl-bits { answer | blocking | clear-back | clear-forward | idle | seize |
seizure-ack | release-guard } { received | transmit }
View
R2 CAS view
Parameter
answer: Answer signal of R2 line signaling.
blocking: Blocking signal of R2 line signaling.
clear-back: Clear-back signal of R2 line signaling.
clear-forward: Clear-forward signal of R2 line signaling.
idle: Idle signal of R2 line signaling.
seize: Seizure signal of R2 line signaling.
seizure-ack: Seizure acknowledgement signal of R2 line signaling.
release-guard: Release guard signal of R2 line signaling.
received: Indicates that the signaling setting applies to received R2 line signals.
transmit: Indicates that the signaling setting applies to transmitted R2 line signals.
ABCD: ABCD bit pattern of R2 line signaling, in the range of 0000 to 1111.
Table 695 Default values of signals in R2 digital line signaling
Signal
Answer
Blocking
Clear-back
Clear-forward
Idle
Seize
Seizure-ack
Release-guard
Description
Use the
Use the
This command applies to R2 signaling only.
You may need to use this command to accommodate to the ABCD bit pattern
schemes used in different countries.
When you modify the ABCD bit pattern of a signal, you need to modify the ABCD
bit pattern of other signals accordingly so that the whole signaling system can
work normally.
Default rx-bits ABCD
0101
1101
1101
1001
1001
0001
1101
1001
command to configure the ABCD bit pattern for R2 signals.
dl-bits
command to restore the defaults.
undo dl-bits
2653
Default tx-bits ABCD
0101
1101
1101
1001
1001
0001
1101
1001