26.5
Interrupt Sources
When A/D conversion ends, SEND or HEND flag in ADCSR is set to 1. The A/D conversion
end interrupt can be enabled or disabled by ADIE bit in ADCSR.
Figure 26.4 shows the block diagram of A/D conversion end interrupt.
A/D control/status register (ADCSR)
SEND
HEND
ADIE
A/D conversion end
interrupt (ADI)
To interrupt controller
Figure 26.4 Block Diagram of A/D Conversion End Interrupt
Rev. 2.0, 11/00, page 590 of 1037