Scan Mode - Renesas H8SX/1650 Hardware Manual

Renesas 32-bit cisc microcomputer h8sx family / h8sx/1600 series
Table of Contents

Advertisement

ADIE
A/D conversion start
ADST
ADF
Channel 0 (AN0)
Waiting for conversion
operation state
Waiting for
Channel 1 (AN1)
conversion
operation state
Channel 2 (AN2)
Waiting for conversion
operation state
Channel 3 (AN3)
Waiting for conversion
operation state
ADDRA
ADDRB
ADDRC
ADDRD
Note: * ↓ indicates the timing of instruction execution by software.
Figure 14.2 Example of A/D Converter Operation (Single Mode, Channel 1 Selected)
14.4.2

Scan Mode

In scan mode, A/D conversion is to be performed sequentially on the analog inputs of the specified
channels up to four or eight channels.
1. When the ADST bit in ADCSR is set to 1 by software, TPU, TMR, or an external trigger
input, A/D conversion starts on the first channel in the group. Consecutive A/D conversion on
a maximum of four channels (SCANE and SCANS = B'10) or on a maximum of eight
channels (SCANE and SCANS = B'11) can be selected. When consecutive A/D conversion is
performed on four channels, A/D conversion starts on AN4 when CH3 and CH2 = B'01. When
consecutive A/D conversion is performed on eight channels, A/D conversion starts on AN0
when CH3 = B'0.
2. When A/D conversion for each channel is completed, the A/D conversion result is sequentially
transferred to the corresponding ADDR of each channel.
Set
*
Set
*
A/D conversion 1
Waiting for conversion
Set
*
Clear
*
A/D conversion 2
Reading A/D conversion result
A/D conversion result 1
Rev.2.00 Jun. 28, 2007 Page 533 of 666
Section 14 A/D Converter
Clear
*
Waiting for conversion
Reading A/D conversion result
A/D conversion result 2
REJ09B0311-0200

Advertisement

Table of Contents
loading

This manual is also suitable for:

R5s61650cH8sx/1650c

Table of Contents