Synchronous Operation - Renesas H8SX/1650 Hardware Manual

Renesas 32-bit cisc microcomputer h8sx family / h8sx/1600 series
Table of Contents

Advertisement

Section 9 16-Bit Timer Pulse Unit (TPU)
9.4.2

Synchronous Operation

In synchronous operation, the values in multiple TCNT counters can be rewritten simultaneously
(synchronous presetting). Also, multiple TCNT counters can be cleared simultaneously
(synchronous clearing) by making the appropriate setting in TCR.
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 5 can all be designated for synchronous operation.
(1)
Example of Synchronous Operation Setting Procedure
Figure 9.10 shows an example of the synchronous operation setting procedure.
Synchronous operation
selection
Set synchronous
operation
Synchronous presetting
Set TCNT
<Synchronous presetting>
[1] Set the SYNC bits in TSYR corresponding to the channels to be designated for synchronous operation to 1.
[2] When the TCNT counter of any of the channels designated for synchronous operation is written to, the
same value is simultaneously written to the other TCNT counters.
[3] Use bits CCLR2 to CCLR0 in TCR to specify TCNT clearing by input capture/output compare, etc.
[4] Use bits CCLR2 to CCLR0 in TCR to designate synchronous clearing for the counter clearing source.
[5] Set the CST bits in TSTR for the relevant channels to 1, to start the count operation.
Figure 9.10 Example of Synchronous Operation Setting Procedure
Rev.2.00 Jun. 28, 2007 Page 352 of 666
REJ09B0311-0200
[1]
Synchronous clearing
[2]
Clearing
source generation
channel?
Yes
Select counter
clearing source
Start count
<Counter clearing>
No
Set synchronous
[3]
counter clearing
[5]
Start count
<Synchronous clearing>
[4]
[5]