REJ10B0173-0100
H8SX/1520 Group FP-100M
User System Interface Cable
User's Manual
Renesas Microcomputer Development Environment System
HS1527ECH61H
Rev.1.00
Revision Date: Jan. 12, 2005

Advertisement

Table of Contents
loading

Summary of Contents for Renesas H8SX/1520

  • Page 1 REJ10B0173-0100 H8SX/1520 Group FP-100M User System Interface Cable User’s Manual Renesas Microcomputer Development Environment System HS1527ECH61H Rev.1.00 Revision Date: Jan. 12, 2005...
  • Page 2 (iii) prevention against any malfunction or mishap. 1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corp.
  • Page 3 Preface The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an FP-100M package for the H8SX/1520 group MCU on the user system.
  • Page 4: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System... 5 2.2.1 Installing IC Socket... 5 2.2.2 Soldering IC Socket ... 5 2.2.3 Inserting Cable Head... 6 2.2.4 Fastening Cable Head ...
  • Page 5: Section 1 Configuration

    Section 1 Configuration Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package IC socket on the user system. Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP-100M package. To emulator station Screws (M2.6 x 6 mm) with flat washers Figure 1 HS1527ECH61H User System Interface Cable...
  • Page 6 Table 1 lists the HS1527ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1527ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2.6 x 12 mm) Screws (M2.6 x 6 mm) Documentation Quantity Remarks...
  • Page 7: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 8 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2). E6000H RENESAS HS1527KEPH60H emulator station Figure 2 Example of the HS1527KEPH60H Emulator Station Cable body connector...
  • Page 9: Connecting User System Interface Cable To User System

    Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 10: Inserting Cable Head

    2.2.3 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100M package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
  • Page 11 Fasten the user system interface cable head to the IC socket for an FP-100M package on the user system with the four screws (M2.6 tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 12: Fastening Cable Body

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jigs Remove jig Cable head User system Figure 4 Fastening Cable Body...
  • Page 13: Recommended Dimensions For User System Mount Pad

    Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100M package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
  • Page 14: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 29.5 17.0 63.50 Unit: mm Tolerance: ±0.5 mm...
  • Page 15: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head User system Figure 7 Resulting Dimensions after Connecting User System Interface Cable IC socket (IC149-100-054-B51 manufactured by...
  • Page 16: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 17 Screws (M2.6 x 6 mm) with flat washers Socket cover Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System...
  • Page 18: Section 4 Verifying Operation

    EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and XTAL terminals. For details, refer to the H8SX/1520 Group Hardware Manual. To use the crystal oscillator mounted on the EV-chip board Install a crystal oscillator into the crystal oscillator terminals on the EV-chip board.
  • Page 19: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS1527KEPH60H emulator. Do not use this cable with any other emulator station.
  • Page 20 For details on the differences between the target MCU and the emulator, refer to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges of input voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual. Insert the jumper pin in the P4 short connector so that the higher voltage between AVcc0 and AVcc1 is selected.
  • Page 21 H8SX/1520 Group FP-100M User System Interface Cable Publication Date: Rev.1.00, January 12, 2005 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2005. Renesas Technology Corp., All rights reserved. Printed in Japan.
  • Page 22 Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com RENESAS SALES OFFICES Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.