Renesas H8SX/1653 User Manual
Renesas H8SX/1653 User Manual

Renesas H8SX/1653 User Manual

Renesas interface board user's manual

Advertisement

Quick Links

REJ10B0200-0200
H8SX/1653 Group E6000H TFP-120
User System Interface Board
HS1653ECN61H User's Manual
Renesas Microcomputer Development Environment System
HS1653ECN61HE
Rev.2.00
Revision Date: Dec. 09, 2005

Advertisement

Table of Contents
loading

Summary of Contents for Renesas H8SX/1653

  • Page 1 REJ10B0200-0200 H8SX/1653 Group E6000H TFP-120 User System Interface Board HS1653ECN61H User’s Manual Renesas Microcomputer Development Environment System HS1653ECN61HE Rev.2.00 Revision Date: Dec. 09, 2005...
  • Page 3 (iii) prevention against any malfunction or mishap. 1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corp.
  • Page 5: Important Information

    Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface board. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
  • Page 6: Limited Warranty

    User system interface boards are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas’...
  • Page 7 This user's manual and user system interface board are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas’ prior written consent.
  • Page 8 • READ this user's manual before using this user system interface board. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface board until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
  • Page 9 Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
  • Page 10 The HS1653ECN61H is a user system interface board that connects a user system for the H8SX/1653 TFP-120 package to the H8SX/1650 E6000H emulator (HS1650EPH60H). Emulation of the H8SX/1653 group is only possible when this user system interface board is connected to the HS1650EPH60H.
  • Page 11: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Board to User System... 3 2.1.1 Installing IC Socket... 4 2.1.2 Soldering IC Socket ... 4 2.1.3 Installing IC Socket... 4 2.1.4 Fastening IC Socket Connector... 5 Exchanging the Spacer of the Evaluation Chip Board... 7 Connecting User System Interface Board to Evaluation Chip Board ...
  • Page 12: Section 1 Configuration

    TFP-120 package. Please make sure you have all of these components when unpacking. Screws (M2 8 mm) with flat washers Socket cover Figure 1 User System Interface Board for the H8SX/1653 TFP-120 Package Section 1 Configuration Spacer User system Evaluation chip board...
  • Page 13 Use an IC149-120-043-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-120 package IC socket on the user system. Table 1 HS1653ECN61H Components No. Component User system interface board IC socket Socket cover Screw (M2 x 12 mm) Screw (M2 x 8 mm) Spacers (2.6MP x 25 mm) 2 Spacers (2.6MQ x 16 mm) 4 User’s manual...
  • Page 14: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Board to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 15: Installing Ic Socket

    To connect the cable head to the user system, follow the instructions below. 2.1.1 Installing IC Socket After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of the IC socket for a TFP-120 package, and fasten it to the user system before soldering. 2.1.2 Soldering IC Socket After fastening, solder the IC socket for a TFP-120 package to the user system.
  • Page 16: Fastening Ic Socket Connector

    2.1.4 Fastening IC Socket Connector 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.294 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 17 User system Figure 2 Connecting User System Interface Board to User System Screws (M2 12 mm) with flat washers (for fastening cable head) User system interface board Pin 1 IC socket (IC149-120-043-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.)
  • Page 18: Exchanging The Spacer Of The Evaluation Chip Board

    Exchanging the Spacer of the Evaluation Chip Board While the user system interface board is connected to the user system, be careful not to apply load. Exchange the spacer (2.6MP 25 mm) provided for the user system interface board. 10 mm) of the evaluation chip board with another spacer (2.6MP Evaluation chip board Spacer (2.6MP...
  • Page 19: Connecting User System Interface Board To Evaluation Chip Board

    Connecting User System Interface Board to Evaluation Chip Board Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
  • Page 20 Evaluation chip board Figure 4 Connecting User System Interface Board to Evaluation Chip Board Connector No. Evaluation Chip Board Connector No. UCN1 UCN2 User system interface board Board Connector No. UCN1 UCN2...
  • Page 21: Recommended Dimensions For User System Mount Pad (Footprint)

    Recommended Dimensions for User System Mount Pad (Footprint) Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a TFP-120 package (IC149-120-043-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
  • Page 22: Dimensions For Evaluation Chip Board And User System Interface Board

    Dimensions for Evaluation Chip Board and User System Interface Board The dimensions for the evaluation chip board and the user system interface board are shown in figure 6. Figure 6 Dimensions for Evaluation Chip Board and User System Interface Board 140.0 Evaluation chip board 118.5...
  • Page 23: Resulting Dimensions After Connecting User System Interface Board

    Resulting Dimensions after Connecting User System Interface Board The resulting dimensions, after connecting the user system interface board to the user system, are shown in figure 7. Spacer ( 5.8) Figure 7 Resulting Dimensions after Connecting User System Interface Board Evaluation chip board IC socket (IC149-120-043-B51...
  • Page 24: Using The Emulator Without Connecting User System

    Using the Emulator without Connecting User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 25 Figure 8 SW1 Jumper Socket Spacer (2.6MQ x 16 mm) Figure 9 Attaching Spacers...
  • Page 26: Section 3 User System Interface Circuits

    Section 3 User System Interface Circuits The following user interface circuits are required for the emulator when the user system interface board is in use. Sub-MCU MD_CLK PM0-PM4 VBUS DrVcc USD- USD+ DrVss Figure 10 User System Interface Circuit (1) Note: The power-supply circuit shown above is turned on/off by the setting of the SW1 jumper pin on HS1653ECN61H.
  • Page 27 Figure 11 User System Interface Circuit (2) Sub-MCU Figure 12 User System Interface Circuit (3) SN74CB3Q3306A SN74CB3Q3306A SN74CB3Q3306A SN74CB3Q3306A User system User system...
  • Page 28 User system EPM7128 UHC14 VHC244 47 k _RES _RES EPM7128 Figure 13 User System Interface Circuit (4)
  • Page 29: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). 2. Verify the user system interface cable connections by checking the pin states with the CHECK command (emulator command) and checking the bus states with the FILL command (emulator command).
  • Page 30 To use the crystal oscillator mounted on the evaluation chip board Install the crystal oscillator into the crystal oscillator terminals on the evaluation chip board. Crystal oscillator terminals Figure 15 Installing the Clock Oscillator Enlarged view Crystal oscillator Evaluation chip board...
  • Page 31: Section 5 Notice

    1. Before connecting any parts or cables, make sure that pin 1 on the both sides are correctly aligned. 2. Do not apply excessive force to the user system interface board while it is connected to the user system. 3. The dimensions of the recommended mount pad for the IC socket for this user system interface board are different from those of the MCU.
  • Page 32 8. When this emulator is used without connecting to the user system, ensure that the SW1 jumper pin is inserted to [OFF]. Failure to do so will damage the emulator product, user system interface cable, and user system. 9. To connect the emulator to the user system, ensure that the SW1 jumper pin is inserted to [ON].
  • Page 33: Section 6 Restrictions

    Section 6 Restrictions There are the following restrictions on emulation of the H8SX/1653 group when the user system interface board is connected to the emulator. 1. The USB clock frequency is fixed to 48 MHz regardless of the EXTAL input.
  • Page 34 Publication Date: Rev.1.00, November 11, 2004 Rev.2.00, December 9, 2005 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div. Renesas Solutions Corp. © 2005. Renesas Technology Corp., All rights reserved. Printed in Japan.
  • Page 35 Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com RENESAS SALES OFFICES Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
  • Page 36 H8SX/1653 Group E6000H TFP-120 User System Interface Board HS1653ECN61H User’s Manual 2-6-2, Ote-machi, Chiyoda-ku, Tokyo, 100-0004, Japan...

This manual is also suitable for:

Hs1653ecn61h

Table of Contents