Synchronous Operation

In synchronous operation, the values in a number of TCNT counters can be rewritten
simultaneously (synchronous presetting). Also, a number of TCNT counters can be cleared
simultaneously by making the appropriate setting in TCR (synchronous clearing).
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 5 can all be designated for synchronous operation.
Example of Synchronous Operation Setting Procedure: Figure 10.10 shows an example of the
synchronous operation setting procedure.
Synchronous operation
selection
Set synchronous
operation
Synchronous presetting
Set TCNT
<Synchronous presetting>
[1]
Set to 1 the SYNC bits in TSYR corresponding to the channels to be designated for synchronous
operation.
[2]
When the TCNT counter of any of the channels designated for synchronous operation is
written to, the same value is simultaneously written to the other TCNT counters.
[3]
Use bits CCLR2 to CCLR0 in TCR to specify TCNT clearing by input capture/output compare,
etc.
[4]
Use bits CCLR2 to CCLR0 in TCR to designate synchronous clearing for the counter clearing
source.
[5]
Set to 1 the CST bits in TSTR for the relevant channels, to start the count operation.

Figure 10.10 Example of Synchronous Operation Setting Procedure

[1]
Synchronous clearing
[2]
Clearing
source generation
channel?
Yes
Select counter
clearing source
Start count
<Counter clearing>
Section 10 16-Bit Timer Pulse Unit (TPU)
No
Set synchronous
[3]
counter clearing
[4]
Start count
<Synchronous clearing>
Rev. 6.00 Mar 15, 2006 page 203 of 570