When using both TDMs with dynamic changes, as in Figure 21-7, the initial current-route
RAM byte addresses are as follows:
¥ 0Ð63 RXa route
¥ 128Ð191 RXb route
¥ 256Ð319TXa route
¥ 384Ð447 TXb route
The shadow RAMs are at addresses:
¥ 64Ð127 RXa route
¥ 192Ð255 RXb route
¥ 320Ð383 TXa route
¥ 448Ð511TXb route
MOTOROLA
Part V. The Communications Processor Module
Chapter 21. Serial Interface