Motorola MPC860 PowerQUICC User Manual page 656

Table of Contents

Advertisement

Part V. The Communications Processor Module
Decoding Method
NRZI Mark
NRZI Space
FM0
FM1
Manchester
Differential Manchester
The DPLL can also be used to invert the data stream of a transfer. This feature is available
in all encodings, including standard NRZ format. Also, when the transmitter is idling, the
DPLL can either force TXD high or continue encoding the data supplied to it.
The DPLL is used for UART encoding/decoding, which gives the option of selecting the
divide ratio in the UART decoding process (8´, 16´, or 32´). Typically, 16´ is used.
The maximum data rate supported with the DPLL is 3.125 MHz, assuming a 25-MHz
system clock and the 8´ ratio (25 MHz/8 = 3.125 MHz). Thus, the frequency applied to
CLKx or generated by an internal baud rate generator may be up to 25 MHz on a 25-MHz
MPC8560Voyager, if the DPLL 8´, 16´, or 32´ option is used.
Note the 1:2 system clock/serial clock ratio does not apply when the DPLL is used to
recover the clock in the 8´, 16´, or 32´ modes. Synchronization occurs internally after the
DPLL generates the Rx clock. Therefore, even the fastest DPLL clock generation (the 8´
option) easily meets the required 1:2 ratio clocking limit.
22.3.5.1 Encoding Data with a DPLL
Each SCC contains a DPLL unit that can be programmed to encode and decode the SCC
data as NRZ, NRZI Mark, NRZI Space, FM0, FM1, Manchester, and Differential
Manchester. Figure 22-15 shows the different encoding methods.
22-24
Table 22-7. Preamble Requirements
Preamble Pattern
All zeros
All ones
All ones
All zeros
101010...10
All ones
MPC860 PowerQUICC UserÕs Manual
Minimum Preamble Length Required
8-bit
8-bit
8-bit
8-bit
8-bit
8-bit
MOTOROLA

Advertisement

Table of Contents
loading