AX- Ser i es Mo t i o n Co n t r o l l er I n s t r u c t i o n s Ma n u a l
Name
Function
Specify the
Axis
axis.
*Note:
AXIS_REF_DML (FB): All function blocks contain this variable, which works as the starting program for function blocks.
Function
bRegulatorOn and bDriveStart are effective only when bEnable is True.
When bEnable, bRegulatorOn and bDriveStart are all True, bStatus changes to True and nAxisState (state machine)
changes to Standstill
When bEnable and bRegulatorOn are True and then bDriveStart is set to False, nAxisState (state machine) changes
to Stopping.
When bEnable and bDriveStart are True and then bRegulatorOn is set to False, nAxisState (state machine) changes
to Disabled.
When the axis state machine is under Standstill, Delta servo ASDA-xx-E Series runs MC_Stop_DML, and the bStatus
of MC_Power_DML will be False.
Troubleshooting
When an error occurs in the instruction execution or the axis enters Errorstop state, bError changes to True and the
axis stops running. To confirm current error state, see the error code in ErrorID.
Programming Example
For the example, refer to the programming example for MC_Power function block
For function block Axis parameters, enter that of the positioning axis.
2.3.3.2
MC_Stop_DML
Supported Devices: AX-308E, AX-364E
MC_Stop_DML decelerates the specified axis to a stop.
FB/FC
Instruction
FB
MC_Stop_DML
Data Type
AXIS_REF_DML*
AXIS_REF_DML
ST Language
Setting Value
Graphic Expression
Ch a p t er 2
Timing to Take Effect
When bEnable turns to True.
4 0 5