AX- Ser i es Mo t i o n Co n t r o l l er I n s t r u c t i o n s Ma n u a l
Timing Diagram
The FirstOnPosition and LastOnPosition of Switch 1 on Track1 are set to 90 and 95 respectively with Hysteresis
set to 10, which means the switch will be turned off after the axis position passing the interval (80~100).
Track 1 is switched to ON when the axis reaches position 90 and not able to be switched to OFF at position 95
until the axis passes the hysteresis interval.
When the axis moves reversely to position 95, the switch will be turned ON again and remains, for the reason
that the axis position stays within the hysteresis interval (105~85).