2.3.1.12 DMC_GroupInterrupt
Supported Devices: AX-308E, AX-364E
DMC_GroupInterrupt makes the current motion pause, and it can be used with DMC_GroupContinue to restore the motion.
FB/FC
Instruction
FB
DMC_GroupInterrupt
DMC_GroupInterrupt_instance(
AxisGroup: = ,
bExecute: = ,
lrDeceleration: = ,
lrJerk: = ,
bDone=> ,
bBusy=> ,
bCommandAborted=> ,
bError=> ,
ErrorID=> );
Inputs
Name
The instruction is run
bExecute
when bExecute changes
lrDeceleration
lrJerk
Outputs
Name
bDone
True when all axes stop with the velocity 0.
bBusy
True when the instruction is triggered to run.
bCommandAborted
True when the instruction is interrupted.
Function
from False to True.
Deceleration
(user unit/s
)
2
Jerk;Jump
(Unit: user unit/s
3
)
Function
Graphic Expression
ST Language
Setting Value
Data Type
(Default Value)
BOOL
True/False (False)
LREAL
Positive (0)
LREAL
Positive (0)
Data Type
Timing to Take Effect
When bExecute turns to True.
When bExecute turns to True.
Output Range (Default Value)
BOOL
True/False (False)
BOOL
True/False (False)
BOOL
True/False (False)
Ch a p t er 2
-
2 2 4