AX- Ser i es Mo t i o n Co n t r o ll er I n s t r uc t i o ns Ma n u a l
Name
Specify the mode for
the tappet point when
PositiveMode
it is passed in the
positive direction.
Specify the mode for
the tappet point when
NegativeMode
it is passed in the
negative direction.
*Note:
One tappet track can be set with multiple tappet points. Maximum 8 tappet points can be written for one tappet track via the
function block.
Outputs
Name
True when the instruction is
bDone
completed.
True when the instruction is
bBusy
triggered to run.
bError
True when an error occurs.
Record the error code when an
ErrorID
error occurs. Refer to Appendix for
error code descriptions.
The Track ID of the new tappet
iTrackID
track
*Note: DMC_ERROR: Enumeration (ENUM)
Output Update Timing
Name
bDone
bBusy
bError
Function
Data Type
DMC_CAM
TAPPETACTION
DMC_CAM
TAPPETACTION
Function
Timing for shifting to True
When the instruction is completed.
When bExecute is True.
When an error occurs in the execution
conditions or input values for the instruction.
Setting Value
(Default Value)

0: TAPPETACTION_none

1: TAPPETACTION_on

2: TAPPETACTION_off

3: TAPPETACTION_inv

[0..7]
*

4: TAPPETACTION_time

(TAPPETACTION_none)
0: TAPPETACTION_none
1: TAPPETACTION_on
2: TAPPETACTION_off
3: TAPPETACTION_inv
[0..7]
*
4: TAPPETACTION_time
(TAPPETACTION_none)
Data Type
BOOL
BOOL
BOOL

DMC_ERROR

*
INT
Timing to Take Effect
When bExecute turns
from False to True.
When bExecute turns
from False to True.
Output range (Default Value)
True/False (False)
True/False (False)
True/False (False)
DMC_ERROR (DMC_NO_ERROR)
1~512
Timing for shifting to False
When bError is True.
When bExecute turns to False.
When bDone is True.
When bError is True.
When bExecute turns from True to False