AX- Ser i es Mo t i o n Co n t r o l l er I n s t r u c t i o n s Ma n u a l
Name
Function
Axis
Specify the axis.
*Note: AXIS_REF_SM3(FB): Every function block contains this variable, which works as the starting program for function blocks.
Function
When Enable is True, bRegulatorOn and bDriveStart are effective.
When Enable, bRegulatorOn and bDriveStart are True. Status turns to True and nAxisState turns to Standstill.
When Enable and bRegulatorOn are True, set DriveStart to be False which nAxisState(axis status) turns to Stopping.
When Enable and bDriveStart are True, set RegulatorOn to be False which nAxisState(axis status) directly turns to
Disabled.
Timing Diagram
Troubleshooting
If an error occurs during the execution of the instruction or the axis is in an Errorstop state, Error turns to True and
the axis will be decelerated to a stop. You can refer to ErrorID (Error Code) to address the problem.
Example:
Example1: The following example explains the movement of a moving axis when bRegulatorOn of MC_Power turns to
False.
Data Type
AXIS_REF_SM3*
Setting Value
(Default Value)
AXIS_REF_SM3
When Enable turns to True.
Ch a p t er 2
Timing to Take Effect
1 0 1