Delta AX Series Instruction Manual page 333

Motion controller
Hide thumbs Also See for AX Series:
Table of Contents

Advertisement

AX- Ser i es Mo t i o n Co n t r o l l er I n s t r u c t i o n s Ma n u a l
Mode
TAPPETACTION_none
TAPPETACTION_on
TAPPETACTION_off
TAPPETACTION_inv
TAPPETACTION_time
*Note:
When the mode is set to TAPPETACTION_time in this function block, the tappet switch will turn off after being ON for a fixed 100
ms.
Troubleshooting
When an error occurs during the execution of the instruction or the axis enters "Errorstop" state, bError will change to
True and the axis stops running. Refer to ErrorID (Error Code) to address the problem.
Programming Example
The example explains the action principle for DMC_CamDeleteTappet by deleting the specified track data from the tappet
table.
Initial tappets setting
Function block setting
See the tappet table before the function block is run
Track ID
1
Function
No action
ON
OFF
Invert
ON
Master axis position
100
The tappet switch does not take an action when the master axis
passes the point.
The tappet switch is enabled when the master axis passes the point.
The tappet switch is disabled when the master axis passes the point.
The tappet switch status is inverted when the master axis passes the
point.
When the master axis passes the point, the tappet switch is ON for
a set period of time and then turns OFF.
Direction
Negative
Action
Mode
TAPPETACTION_off
Ch a p t er 2
3 2 8