2.3.2.7 DMC_GroupReset
Supported Devices: AX-308E, AX-364E
FB/FC
Instruction
FB
DMC_GroupReset
DMC_GroupReset_instance(
AxisGroup: = ,
bExecute: = ,
bDone=> ,
bBusy=> ,
bError=> ,
ErrorID=> ) ;
Inputs
Name
The instruction is run when
bExecute
bExecute changes from False
to True.
Outputs
Name
bDone
True when the instruction is completed.
True when the instruction is triggered to
bBusy
run.
True when an error occurs in execution of
bError
the instruction.
Record the error code when an error
ErrorID
occurs. Refer to Appendix for error code
descriptions.
*Note: DMC_ERROR: Enumeration (ENUM)
Output Update Timing
ST Language
Function
Data Type
Function
Graphic Expression
Setting Value
(Default Value)
BOOL
True/False (False)
Data Type
BOOL
BOOL
BOOL
DMC_ERROR
*
Timing to Take Effect
-
Output range (Default Value)
True/False (False)
True/False (False)
True/False (False)
DMC_ERROR (DMC_NO_ERROR)
Ch a p t er 2