When bExecute of DMC_GroupStop changes to True, bCommandAboted of MoveLinearRelative changes to
True and axes start to decelerate to a stop. Meanwhile the axis group stays in GroupStopping state.
When the velocities of axes reach 0, bDone of DMC_GroupStop changes to True and the axis group holds
GroupStopping state.
When bExecute of DMC_GroupStop changes to False, the state of axes changes from GroupStopping into
StandBy.
2.3.1.8 DMC_GroupHalt
Supported Devices: AX-308E, AX-364E
DMC_GroupHalt decelerates the axis group in motion to a pause.
Ch a p t er 2