Delta AX Series Instruction Manual page 324

Motion controller
Hide thumbs Also See for AX Series:
Table of Contents

Advertisement

AX- Ser i es Mo t i o n Co n t r o l l er I n s t r u c t i o n s Ma n u a l
Programming Example
The example explains the action principle for DMC_CamWriteTappetValue by writing the tappet data of Track ID 1.
Initial setting for tappet points
Function block setting
Input 1 for uiTrackID. Refer to the figure below for the setup of IrMasterPos, PositiveMode and NegativeMode.
The tappet table before the function block is run
Track ID
1
Master axis position
100
Direction
Negative
Ch a p t er 2
Passing mode
TAPPETACTION_off
3 1 9