Tappetaction_None; Dmc_Error - Delta AX Series Instruction Manual

Motion controller
Hide thumbs Also See for AX Series:
Table of Contents

Advertisement

AX- Ser i es Mo t i o n Co n t r o l l er I n s t r u c t i o n s Ma n u a l
Name
Function
positive direction.
Specify the mode
for the tappet point
NegativeMode
when it has
passed in the
negative direction.
*Note:
One tappet track can be set with multiple tappet points. Maximum 8 tappet points can be written for one tappet track via the
function block.
Outputs
Name
When the output is valid.
bDone
True when the instruction is
bBusy
triggered to run.
bError
True when an error occurs.
Record the error code when an
ErrorID
error occurs. Refer to Appendix for
error code descriptions.
*Note: DMC_ERROR: Enumeration (ENUM)
Output Update Timing
Name
When the instruction is completed.
bDone
When bExecute turns to True.
bBusy
When an error occurs in the execution conditions
or input values for the instruction.
bError
Timing Diagram
Data Type
DMC_CAMTAPPETACTION[0..7]
Function
Timing for shifting to True
Setting Value
(Default Value)
4: TAPPETACTION_time

(TAPPETACTION_none)

0: TAPPETACTION_none
1: TAPPETACTION_on
2: TAPPETACTION_off
*
3: TAPPETACTION_inv
4: TAPPETACTION_time
(TAPPETACTION_none)
Data Type
BOOL
BOOL
BOOL

DMC_ERROR

*
When bError turns to True.
When bExecute turns to False.
When bDone turns to True.
When bError turns to True.
When bExecute turns from True to False.
Timing to Take
When bExecute
turns from False to
True.
Output range (Default Value)
True/False (False)
True/False (False)
True/False (False)
DMC_ERROR (DMC_NO_ERROR)
Timing for shifting to False
Ch a p t er 2
Effect
3 1 7

Advertisement

Table of Contents
loading

Table of Contents