Command Manual – IPv6 Configuration
H3C S7500E Series Ethernet Switches
<Sysname2> system-view
[Sysname2] interface Tunnel 1/0/3
[Sysname2-Tunnel1/0/3] source 192.100.1.1
[Sysname2-Tunnel1/0/3] destination 193.101.1.1

3.1.3 display interface tunnel

Syntax
display interface tunnel [ number ]
View
Any view
Parameters
number: Tunnel interface number. If the number argument is not specified, the
information of all tunnel interfaces will be displayed.
Description
Use the display interface tunnel command to display related information of a
specified tunnel interface, such as source address, destination address, and
encapsulation mode.
Related commands: interface tunnel, source, destination, tunnel-protocol.
Examples
# Display the information of the interface Tunnel 1/0/3.
<Sysname> display interface Tunnel1/0/3
Tunnel1/0/3 current state: UP
Line protocol current state: UP
Description: Tunnel1/0/3 Interface
The Maximum Transmit Unit is 64000
Internet Address is 10.1.2.1/24 Primary
Encapsulation is TUNNEL, aggregation ID not set
Tunnel source 192.13.2.1, destination 192.13.2.2
Tunnel protocol/transport IPv6/IP
Last 300 seconds input:
Last 300 seconds output:
361 packets input,
0 input error
361 packets output,
0 output error
Chapter 3 Tunneling Configuration Commands
0 bytes/sec, 0 packets/sec
0 bytes/sec, 0 packets/sec
9953388 bytes
30324 bytes
3-3