H3C S7500E Series Command Manual page 714

Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

Command Manual – IPv6 Configuration
H3C S7500E Series Ethernet Switches
Description
Use the display ipv6 interface tunnel command to display related IPv6 information of
a specified tunnel interface, including link state, IPv6 protocol state, and IPv6 address.
Examples
# Display the information of the interface Tunnel 1/0/3.
<Sysname> display ipv6 interface Tunnel1/0/3
Tunnel1/0/3 current state :UP
Line protocol current state :UP
IPv6 is enabled, link-local address is FE80::101:101
Global unicast address(es):
2002:101:101::1, subnet is 2002::/16
Joined group address(es):
FF02::1:FF01:101
FF02::1:FF00:1
FF02::2
FF02::1
MTU is 1500 bytes
ND reachable time is 30000 milliseconds
ND retransmit interval is 1000 milliseconds
Hosts use stateless autoconfig for addresses
Table 3-2 Description on fields of the display interface tunnel command
Tunnel1/0/3 current state: UP
Line protocol current state: UP
IPv6 is enabled
link-local address
Global unicast address(es)
Joined group address(es)
MTU is 1500 bytes
ND reachable time
ND retransmit interval
Field
3-5
Chapter 3 Tunneling Configuration Commands
Description
The physical layer of the tunnel interface is
reachable.
The link layer of the tunnel interface is
reachable.
Enables IPv6 on a tunnel interface
Link-local address of a tunnel interface
Aggregatable global unicast address of a tunnel
interface.
Multicast address of a tunnel interface.
Size of the MTU in a tunnel. The MTU in this
example is 1,500 bytes.
Neighbor reachable time
Interval for retransmitting a neighbor discovery
message.

Advertisement

Table of Contents
loading