Command Manual – Multicast
H3C S7500E Series Ethernet Switches
3.1.19 last-member-query-interval
Syntax
last-member-query-interval interval
undo last-member-query-interval
View
IGMP view
Parameters
interval: Last-member query interval in seconds, with an effective range of 1 to 5.
Description
Use the last-member-query-interval command to configure the global IGMP
last-member query interval.
Use the undo last-member-query-interval command to restore the system default.
By default, the IGMP last-member query interval is 1 second.
Related commands: igmp last-member-query-interval, robust-count, display igmp
interface.
Examples
# Set the global IGMP last-member interval to 3 seconds.
<Sysname> system-view
[Sysname] igmp
[Sysname-igmp] last-member-query-interval 3
3.1.20 max-response-time
Syntax
max-response-time interval
undo igmp max-response-time
View
IGMP view
Parameters
interval: Maximum response time for IGMP general queries in seconds, with an
effective range of 1 to 25.
Chapter 3 IGMP Configuration Commands