H3C S7500E Series Command Manual page 834

Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

Command Manual – Multicast
H3C S7500E Series Ethernet Switches
Examples
# Set the state refresh interval to 70 seconds.
<Sysname> system-view
[Sysname] pim
[Sysname-pim] state-refresh-interval 70
4.1.60 state-refresh-rate-limit
Syntax
state-refresh-rate-limit interval
undo state-refresh-rate-limit
View
PIM view
Parameters
interval: Time to wait before receiving a new refresh message, in seconds and with an
effective range of 1 to 65535.
Description
Use the state-refresh-rate-limit command to configure the time the router must wait
before receiving a new state refresh message.
Use the undo state-refresh-rate-limit command to restore the system default.
By default, the device waits 30 seconds before receiving a new state refresh message.
Related
state-refresh-ttl.
Examples
# Configure the state refresh interval to 45 seconds.
<Sysname> system-view
[Sysname] pim
[Sysname-pim] state-refresh-rate-limit 45
4.1.61 state-refresh-ttl
Syntax
state-refresh-ttl ttl-value
undo state-refresh-ttl
commands:
pim
Chapter 4 PIM Configuration Commands
state-refresh-capable,
4-52
state-refresh-interval,

Advertisement

Table of Contents
loading

Table of Contents