H3C S7500E Series Command Manual page 933

Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

Command Manual – AAA RADIUS HWTACACS
H3C S7500E Series Ethernet Switches
[Sysname] domain default enable aabbcc.net
1.1.23 idle-cut
Syntax
idle-cut { disable | enable minute }
View
ISP domain view
Parameters
disable: Disables the idle cut function.
enable minute: Enables the idle cut function. The minute argument refers to the
allowed idle duration, in the range 1 to 120 minutes.
Description
Use the idle-cut command to enable or disable the idle cut function.
By default, the function is disabled.
Related commands: domain.
Examples
# Enable the idle cut function and set the idle threshold to 50 minutes for ISP domain
aabbcc.net.
<Sysname> system-view
[Sysname] domain aabbcc.net
[Sysname-isp-aabbcc.net] idle-cut enable 50
1.1.24 level
Syntax
level level
undo level
View
Local user view
Parameters
level: Priority level for the user, which can be 0 for visit level, 1 for monitor level, 2 for
system level, and 3 for manage level. A smaller number means a lower priority.
Chapter 1 AAA/RADIUS/HWTACACS
1-24
Configuration Commands

Advertisement