13-22
Integration Volume
13.5 NORTHERN TELECOM TESTING AND INSTALLATION
This section describes the procedures for installation and testing of NPIC Adaptive Integration for the
Octel 200/300. These tests verify that NPIC Adaptive Integration works correctly with the PBX. Some of
the tests are made before the Octel 200/300 is connected to the PBX. Always check the PBX for correct
operation after any changes are made to the system.
This section presents detailed information for the test procedures and NPIC installation. It should be
performed in the following order:
1. Configure test extensions
2. Test M1
3. Install NPIC card
4. Test Adaptive Integration
.
These tests assume that no other calls are being made into the Octel 200/300. If the Octel 200/300
receives other calls, the test results could be invalid.
The following items are required for testing:
Quantity Description
1
1
1
3
1
Configuring the Test Extensions
For testing purposes, three additional digital extensions must be configured in the M1 before performing
the tests described in the following subsections.
The numbers for these extensions must be consistent with the format of the mailbox numbers in the Octel
200/300 USER Table. For example, the first digit and the number of digits in the extensions must
correspond to the mailbox numbering scheme.
For the test procedures, the phones are referred to as phone A, phone B, and phone C. Configure the test
extensions as follows:
1. Configure the second extension (phone A) with message-waiting indication.
In the tests that follow, this extension is referred to as EXTA. Phone A must be set up to hunt and
forward calls to the Octel 200/300 message server.
Octel 200/300
S.4.1
Table 13-3 Test Equipment
Terminal/teleprinter directly connected to the Octel 200/300 via RS-232C cable
Hard-copy printout of the Octel 200/300 configuration database
Hard-copy printout of the PBX configuration
2616 digital display phones. This phone is required for testing purposes only, (only
one required if two analog phones are available)
25-port grid−style modular adapter such as the Cinch, Super Mod 25
PB60019-01