12.3-28
Integration Volume
Power-on Routine
Once the APIC card is installed, the red LED comes ON. When selftest diagnostics are complete, the
green LED comes ON. When the card has been initialized and is ready for operation, the red LED goes
OFF within five minutes.
The APIC then verifies operation. Verification takes about two minutes. Once a port is verified as
working, the yellow LED associated with each link is turned ON. If all yellow LEDs do not turn ON,
there is a link problem. Troubleshoot the link using the display phone. If the link is good, replace the
APIC board.
.
The 12 port LEDs on the APIC provide simple visual indication of port status. The APIC port
LEDs always remain OFF while a APIC port is disconnected or while the APIC firmware is
initializing the 7407D link to the PBX. The port LEDs flash briefly during the initialization
process. Once initialization is complete, the port LED reflects port status as follows:
-
-
-
Testing Adaptive Integration
This section describes the procedures for testing Adaptive Integration features. Once the APIC card is
installed and operational and the PBX cable is re-connected to the correct Octel 200/300 ports, proceed
with the following tests.
1. CONFIGURING THE OCTEL 200/300 FOR TEST
Before proceeding, make the following changes to the Octel 200/300 configuration.
.
a.
Add a mailbox that has a mailbox number matching the extension number for phone B. This is
referred to as mailbox B.
b. Assign these attributes to the COS for mailbox B.
Attribute 9
Attribute 15 — TRANSFER TO RINGING
c.
Add a second Octel 200/300 mailbox, that has a mailbox number matching the extension number
for phone A. This is referred to as mailbox A. No attributes should be assigned to the COS for
mailbox A.
d. Check that the ring-no-answer count specified by INFORMATION Table Index 7 is less than the
number of rings specified by System 85 coverage paths for forwarding on RNA.
Octel 200/300
S.4.1
The Port LED is ON solid if a port is off-hook.
The Port LED flashes approximately three times per second while a port is reporting ringing
to the VCU.
The LED flashes approximately ten times per second while a port is reporting a line drop
event (abandoned caller) to the VCU.
These changes are temporary; they are required only for testing.
— MESSAGE WAITING LAMP
(message waiting indication only)