7.2-40
Integration Volume
ON, there is a link problem. Troubleshoot the link using the display phone. If the link is good,
replace the ATTIC board.
6. Use the Courtesy Up command to initialize the integration card. At the @ prompt enter
CU x y
x = slot number; y = unit number
If there are two units, both units would have to be initialized.
Repeat this step for unit 2.
7. Test the system for proper operation.
Once the down LED is OFF, the good LED is ON, and the yellow LEDs are ON, the card is working
properly.

Testing of Adaptive Integration Features

This section describes the procedures for testing Adaptive Integration features, once the ATTIC board is
installed and operational and the PBX 25-pair cable for the Octel 200/300 is re-connected to the correct
the Octel 200/300 ports, proceed as follows:
1. CONFIGURING THE OCTEL 200/300 FOR TEST
Before proceeding, make the following changes to the Octel 200/300 configuration (these
changes are temporary; they are required only for testing).
a.
b. Assign these attributes to the mailbox COS —
c.
d. Be sure the mailbox RNA count specified by INFORMATION Table Index 7 is less than the
2. TESTING PORTS
This test verifies that all System 75 Octel 200/300 port extensions are connected to the correct
Octel 200/300 ports.
.
Octel 200/300
S.4.1
Add a mailbox that has a mailbox number matching the extension number for phone B. This
is referred to as mailbox B.
Attribute 15 — TRANSFER TO RINGING
Attribute 9 — MESSAGE WAITING LAMP
(message waiting indication only)
Add a second the Octel 200/300 mailbox that has a mailbox number matching the extension
number for phone A. This is referred to as mailbox A. No attributes should be assigned to its
COS.
number of rings specified by System 75 coverage paths for forwarding on RNA.
Modify System Parameter 117 to be 0. When testing is complete, modify System Parameter
117 back to 5 rings.