Sic8 I/O Panel Designations; Rs-232-C Pinouts Connecting The M2616 To The Sic8 I/O Panel - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

11-18
Integration Volume
The Octel 200/300 installation kit supports one SIC8 board and contains the following:
Part Number
300-6040-001
520-6007-001
SA10076-05
740-6126-001
I/O Panel
The SIC8 I/O panel connects eight external M2616 modular telephones to the SIC8 board via RS-232C
cables. This assembly mounts at the rear lower panel of the Octel 200/300 cabinet. The M2616 modular
telephone designated for link 1 is connected to IJ1, link 2 in IJ2, link 3 in IJ3, etc. Refer to Figure 11-3
for I/O panel designations. Refer to Figure 11-4 for RS-232C pinouts.
IP1
2616 Modular
Telephone (DCE)
Figure 11-4 RS-232-C Pinouts Connecting the M2616 to the SIC8 I/O Panel
Octel 200/300
S.4.1
Quantity
1
1
1
1
IJ6
IJ5
IJ2
IJ1
Figure 11-3 SIC8 I/O Panel Designations
RS-232C Male-to-Male Connectors
2
3
4
5
7
8
20
Description
SIC8 8-channel board assembly
2-ft. female-to-female 25-pair cable
10 ft. female-to-female 25-pair cable
SIC8 I/O Panel
IJ8
IJ7
IJ4
IJ3
2
3
4
5
7
8
20
To SIC8 I/O
Panel (DTE)
PB60019-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents