12.3-30
Integration Volume
c.
After phone B stops ringing, does the Octel 200/300 respond with "Extension EXTB is
unavailable. Please leave a message at the tone. . . "?
NO
d. Enter
5. INTERNAL CALL TO A BUSY EXTENSION
This test verifies that the Octel 200/300 correctly processes a call forwarded from a busy
extension.
a.
Take phone B off-hook so that it appears busy.
b. From phone A, call phone B. Does the Octel 200/300 answer with the prompt, "Extension EXTB
is unavailable. Please leave a message at the tone. . . "?
NO
c.
Enter
6. EXTERNAL TRUNK CALL TO THE OCTEL 200/300
This test verifies that the Octel 200/300 correctly processes calls from trunks that have been
auto-terminated to the Octel 200/300 hunt group. Be sure to test all such trunk groups.
.
a.
From phone A, call outside of the PBX and back in on a trunk that terminates to the Octel
200/300. Does the Octel 200/300 answer with the greeting configured for the trunk?
NO
b. From the terminal connected to the Octel 200/300, enter the PS command. Does the port that
answered show WFD state?
NO
c.
Enter
d. From the Octel 200/300 terminal, busy out the APIC port that answered the call. Use the
command
TE C 1 x
where x is the port number.
e.
Repeat steps a. through d. for each Octel 200/300 port until all of the ports are busied out.
This is to confirm that each Octel 200/300 port can answer a trunk call.
Octel 200/300
S.4.1
Determine the cause, and correct the problem before continuing.
'
to exit from the Octel 200/300 and hang up phone A.
9
9
Determine the cause, and correct the problem before continuing.
'
to exit from the Octel 200/300. Hang up phone A and phone B.
9
9
1-800 (InWATS) lines can be tested individually, even if they are bands from other areas, by
using planned test numbers. Get these numbers from the CO if you do not already know them.
Determine the cause, and correct the problem before continuing.
'
Determine the cause, and correct the problem before continuing.
'
to exit the Octel 200/300.
9
9
PB60019-01