Avaya Octel 200 Installation And Maintenance Manual page 380

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8.1-28 Integration Volume
c.
Make sure phone C is busy by taking it off-hook. From the Octel 200/300, enter the extension
number associated with mailbox XXXX.
d. After a predetermined interval, the Octel 200/300 should reconnect and at phone A, you should
hear, "Extension (phone C) is busy/unavailable. Please leave a message at the tone, enter
another extension number, or press (zero) for assistance."
e.
Leave a test message for phone C.
.
f.
The Octel 200/300 should now initiate message waiting for the extension associated with phone
C.
.
g. Does the Octel 200/300 call the extension associated with phone C?
NO
.
h. Answer phone C, or call Octel 200/300, and enter the mailbox if the indicator is lit. The Octel
200/300 should respond with "...(Name) has X messages. Ready," If set, the security code is
requested.
i.
Enter the security code if asked, and press
j.
Does the message sound clear?
NO
k. Press
"X messages will be erased" enter
"Good-bye."
NO
l.
Hang up the phone. If the extension is equipped with message waiting indication, is the message
waiting indicator turned OFF?
NO
.
Octel 200/300
S.4.1
Messages must be at least 10−15 seconds long to ensure that a valid message is received.
In a system with 8 or less ports, there must be at least 2 idle ports marked for Outcall
before message waiting calls are made. If 9 − 32 ports are configured, the Octel 200/300
makes outcalls when at least three ports are idle. If more than 32 ports are configured,
the Octel 200/300 makes outcalls when at least four ports are idle.
Determine the cause and correct the problem before continuing.
'
If the system is equipped with the message waiting indication option and phone C has
COS Attribute 9 —
LAMP OR DISPLAY PHONE MESSAGE WAITING
activated instead of the phone ringing. The Octel 200/300 can be configured for off-site
and lamp notification, but not for ringing and lamp notification at the same time.
Determine the cause and correct the problem before continuing.
'
to erase the message, then
3
Determine the cause and correct the problem before continuing.
'
Determine the cause and correct the problem before continuing.
'
It may take several seconds for the indicator to turn OFF.
to Listen to the test message.
5
to exit the mailbox. If the Octel 200/300 responds with
9
to exit the system. Does the Octel 200/300 respond with
9
, the light is