Avaya Octel 200 Installation And Maintenance Manual page 238

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

7.2-42
Integration Volume
c.
d. Enter
5. INTERNAL CALL TO A BUSY EXTENSION
This test verifies that the Octel 200/300 correctly processes a call forwarded from a busy
extension.
a.
b. From phone A, call phone B. Does the Octel 200/300 answer with the prompt, "Extension
c.
6. INTERNAL CALL — FAIL-SAFE OPERATION FOR ALL PORTS BUSY
This test verifies that calls to the Octel 200/300 redirect to the designated fail-safe position when
the ports are in use.
a.
b. Put Octel 200/300 ports in the FWD state by entering, at the @ prompt
c.
d. Cancel the FWD state by entering
Octel 200/300
S.4.1
After phone B, stops ringing, does the Octel 200/300 respond with the prompt, "Extension
EXT-B doesn't answer. Please leave a message at the tone. . ."?
NO
Determine the cause and correct the problem before continuing.
'
to exit from the Octel 200/300 and hang up phone A.
9
9
Take phone B off-hook to make it appear busy.
EXT-B is in use. Please leave a message at the tone"?
NO
Determine the cause and correct the problem before continuing.
'
Press
to exit from the Octel 200/300 Hang up phone A and phone B.
9
9
Make sure System Parameters 45 and 46 are set to NONE.
CD x y z
where x is the slot number, y is the first port, and z is the last port to forward.
Using phone TEST1, call the Octel 200/300. Does the operator answer?.
NO
Determine the cause and correct the problem before continuing.
'
CU x y z
where x is the slot number, y is the first port, and z is last port to cancel forwarding.
Note that this test results in many occurrences of Integration peg 11, DIAL ERROR, since all
system ports are out of service. After performing this test, clear the integration pegs using the
Clear Integration command. See the AT&T System 75 Maintenance section in this
chapter.