Card Status
Diagnostic
Link (1-2) Status
Integration Pegs
PB60019-01
AT&T System 85/Definity G2 Adaptive Integration
There are four possible states for the card:
The ATTIC is down and not responding to the
CARD DOWN
software.
Code is down loading to the ATTIC.
DOWN LOAD
The software is downloaded to the card and
INITIALIZATION
setting up operation parameters.
The ATTIC is operational.
CARD UP
The diagnostic code is read from the ATTIC card.
If there are no errors, the DIAGNOSTIC = OK.
-
If an error is found, the DIAGNOSTIC = ERROR DETECTED,
-
CODE = XX.
If this happens, refer to Installation and Maintenance volume, System
Errors and Traffic Pegs chapter, for more information.
There are five possible states for the digit display set links to the
ATTIC:
Link operating properly. No call.
IDLE
Link is handling a call.
ACTIVE
Link is performing message waiting indication.
MSG WAIT
Link is performing SELFTEST.
SLFTST
The link is not getting call information or
DEAD
commands. The link is probably disconnected.
Only the DEAD state is an error condition. If it is found, check the PBX
and the wiring.
LINK-INDEPENDENT PEGS. The following independent pegs are
listed by the LIST INTEGRATION command.
PEG NAME
1
IC ERROR
2
WRONG CNT
3
WDT ERROR
4
MSGW RETRY
5
TIMER RE-ENTRY
DESCRIPTION
Number of times the ATTIC timed
out waiting for Octel 200/300 to
process a reply.
Number of times the ATTIC
processor received an invalid
interrupt.
Number of times the ATTIC
Watchdog timer timed out.
Number of times the ATTIC had to
retry a message waiting lamp
attempt.
The ATTIC 10 ms timer was
interrupted by itself.
Octel 200/300
7.3-43
S.4.1