10.1-20 Integration Volume
INFORMATION Table
PORT COS
SLOTS Table
System Parameters
Octel 200/300
S.4.1
.
Individuals with this COS attribute assigned to their mailbox,
must set their phones to forward on ring-no-answer to the MIC
hunt group. The forwarding can be set up only at each individual
phone, and forwarding may be lost in the event of a PBX restart.
INFORMATION Table Index 25 — QUICK GREETING
ACTIVATION
Modify INFORMATION Table Index 25 to YES to allow selected direct
internal callers to be able to change and turn ON/OFF their personal
greetings without first entering their mailboxes.
COS Attribute 58 — DO NOT USE THIS PORT FOR
INTEGRATION
If there are any line cards in the Octel 200/300 that are not MICs, or if
some special application requires that a MIC port operate in a
non-integrated mode, use this COS attribute to distinguish these ports
from the integrated MIC ports.
ANSWERING MODE. With Mitel SX-200 Digital Adaptive
Integration, all integrated ports should be configured for AX answering
mode to maximize utilization of Octel 200/300 ports.
CONFIGURATION OF PORTS. To maximize system performance
and port usage, all Octel 200/300 ports should be configured for
OUTCALL, except the ports used for message waiting control (if any).
Enable testing on all MIC ports.
Each link for MWI must be programmed as a default or be assigned a
list of COS numbers.
.
Specify only one default message waiting link.
Refer to the Configuration volume, Slots Table chapter, for further
information on configuring the SLOTS Table.
System Parameter 13 — TRANSFER INITIATE CODE
RECONNECT CODE AFTER NO ANSWER
RECONNECT CODE AFTER BUSY
RECONNECT CODE AFTER FAST BUSY
TRANSFER COMPLETE CODE
Modify the value of Transfer Initiate Code to be FE. Modify the value
of all Reconnect Codes to be F, and modify the value of Transfer
Complete Code to be NONE.
System Parameter 16 — ALTERNATE TRANSFER INITIATE
CODE
ALTERNATE RECONNECT CODE AFTER NO ANSWER
ALTERNATE RECONNECT CODE AFTER BUSY
ALTERNATE RECONNECT CODE AFTER FAST BUSY
ALTERNATE TRANSFER COMPLETE CODE
Modify the value of Alternate Transfer Initiate Code to be FE. Modify
the value of all Alternate Reconnect Codes to be F, and modify the
value of Alternate Transfer Complete Code to be NONE.