17.3 INSTALLING THE DTIC
The DTIC-E1 can be configured in slots A1 − A6 in the Octel 200 and in slots A1 − A11 in the Octel 300.
The P1 − P11 connectors on the Octel 200/300 use a 50–pin male telco connector. The Amphenol to BNC
Converter fits into that connector and provides a way to attach the twisted pair (120 ohm) or coax cable (75
Ohm) from the message server to the switch.
The hardware for the QSIG installation consists of three parts:
DTIC-E1
-
Refer to the Installation and Maintenance volume, DTIC chapter for information about installing,
configuring and troubleshooting the card, and to the Hardware Replacement chapter for information
regarding DTIC installation.
Amphenol to BNC converter
-
Part Number 300–6069–011
Part Number 300–6075–001
Grounding Strip
-
PB60019-01
Amphenol to coax DTIC-E1 adapter, 75–ohm converter
Amphenol to twisted pair, 120–ohm converter
QSIG Integration
17−7
Octel 200/300
S.4.1