Avaya Octel 200 Installation And Maintenance Manual page 166

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

7.1-28
Integration Volume
System Parameters
TRUNK GROUP Table
Octel 200/300
S.4.1
System Parameter 3 — PBX MODEL
Select the model number of the telephone system. For DEFINITY G3i,
select 3 (ATT).
System Parameter 85 — RECONNECT CODE AFTER 3RD
PARTY HUNG-UP.
Modify System Parameter 85 to be FDF.
System Parameter 116 — SHOULD INTEGRATION BE
ACTIVATED?
Modify System Parameter 116 to be YES.
System Parameter 117 — RINGBACKS BEFORE ANSWERING
AX PORT
Modify System Parameter 117 to be 5. This gives extra time to receive
the call records from the PBX.
.
The Octel 200/300 normally answers the call immediately within
one ring upon receiving a call record from the ATTIC. This
system parameter provides a fail-safe mode of operation. The
ports answer calls in AX mode in the event that the Octel
200/300 does not receive call information from the digit display
links.
System Parameter 133 — INTEGRATION CARD EXTENSION
Modify this system parameter to be the Octel 200/300 hunt group
access number. This parameter is required only for the system
ring-through test TE L 2. Refer to the Installation and Maintenance
volume, Maintenance Commands chapter, Line Interface Card
Diagnostics section, for more information.
The TRUNK GROUP Table specifies call processing parameters for
different trunk groups by COS.
Configure Trunk Group 0 (zero) with a greeting for use with internal
forwarded calls received without extension numbers. The greeting
should specify that the called party does not have a mailbox on the
system.
Refer to the Configuration volume, TRUNK GROUP Table chapter, for
more information.