Avaya Octel 200 Installation And Maintenance Manual page 408

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8.2-18 Integration Volume
3. PBX FUNCTIONAL TEST (For new install)
This test verifies that each Octel 200/300 port extension can initiate a transfer by doing a
hookswitch flash and a transfer code (or just a hookswitch flash), before entering an extension
number. Also, verify that you can reconnect to the caller when the extension called is not
answered or busy.
.
a.
Connect phone B to the modular adapter position associated with port 1 of the Octel 200/300.
b. From phone A call the extension number associated with phone B.
c.
Answer phone B and perform a hookswitch flash.
d. Does the PBX provide dial tone after the hookswitch flash?
YES
NO
e.
After several ringbacks have occurred (fewer than the PBX configured number of ringbacks
before RNA forwarding), perform a hookswitch flash and reconnect code, if required, to
reconnect to phone A.
f.
Did phone C stop ringing? Did you get reconnected to phone A, that was on hold?
YES
NO
4. PBX BUSY FORWARD TEST
This test verifies that a call to a busy extension forwards to the Octel 200/300 hunt group
a.
Connect phone B to the modular adapter position associated with port 1 of the Octel 200/300.
b. Make phone C busy by taking it off-hook.
c.
From phone A, call the extension number associated with phone C.
d. Does a phantom line on one of the CPI links ring immediately?
NO
e.
From phone B dial the pickup code and the phantom extension number. Verify talk path and
voice quality. Hang up.
Octel 200/300
S.4.1
Before continuing with this test, obtain a hardcopy of the SLOTS Table for reference.
Enter the extension number associated with phone C.
'
Stop and correct the problem before continuing.
'
Connect phone B to the next Octel 200/300 port extension and continue until all
'
extensions for the Octel 200/300 ports have been tested.
Determine the cause and correct the problem before continuing.
'
.
The extension number connected to phone C should start with the same first digit
configured in the
USER T
Determine the cause and correct the problem before continuing.
'
able.
.
PB60019-01